C7200 | C7400 | C7400ER | |
Independent Stations | 2 | 4 | 4 |
Battery voltage range | 1.2 to 15V | 1.2 to 15V | 1.2 to 36V (28.8V for nickel-based) |
Charge/discharge current | 100mA to 4A in 25mA increments | 100mA to 4A in 25mA increments | 100mA to 6A in 25mA increments (With 6A capable Battery Adapters) |
If current is set above 4A (6A), unit automatically scales down to stay within range. Services up to 24Ah batteries. | |||
Maximum charge power | 40W per station; 40W total | 55W per station; 80W total | 75W per station; 170W total |
Maximum discharge power | 35W per station; 70W total | 35W per station; 140W total | 75W per station; 200W total |
Power management | Batteries on a fully loaded system may go on waiting queue. Will resume when demand moderates. | ||
Line voltages | 100 to 240VAC, 50-60Hz 1.5A max | 100 to 240VAC, 50-60Hz 1.75A max | 100 to 120 / 200 to 240VAC, 50-60Hz; 4A max |
Chemistries | Lithium-ion, nickel-metal-hydride, nickel-cadmium, lead-acid | ||
Charge method | Lithium-ion and lead-acid: constant voltage with current limit. Nickel-based: constant current with Reverse Load Charge adjustable from 5-12%. Customized charge methods possible. Automatic full charge detection, safe termination under all conditions. Temperature controlled. | ||
Discharge method | Constant discharge current to end-of-discharge voltage threshold. | ||
Battery adapters | SnapLock™ system; custom and universal types. Contain C-code that configures analyzer to the correct setting. Each adapter has room for 10 C-codes. Re-programmable possible with menu function. Battery Adapters are equipped with a temperature sensor. | ||
Service programs | 18, grouped into Basic, Advanced and Custom programs. Allows manual and automated service. | ||
Security | Level 1 - Off, allows full access, no programming restrictions (default) Level 2 - Low, password protected; allows C-code selection and display options Level 3 - High, password protected; most programming choices locked |
||
Display | 2x40-character LCD, backlit; each station also features RUN, READY, FAIL signal lights. | ||
Power failure recovery | Retains the test data on power failure and resumes when power is restored. Time on power failure and resumption is recorded. | ||
Data ports | RS-232 or USB interfaces to PC (RS-232 recommended). Label printer for direct connection available. | ||
Throughput: QuickTest™ Full Service |
30-40 batteries/hour Fleet of 80 batteries typical |
60-80 batteries/hour Fleet of 160 batteries typical |
60-80 batteries/hour Fleet of 160 batteries typical |
Throughput on full service is based on monthly maintenance. Each analyzer services two battery batches every 24h (day and night run), 20 days per month. | |||
Physical Length Width Height Weight |
12.1”; 307mm 9,4”; 240mm 3.5”; 90mm 7.1 lb; 3.2 kg |
14.4”; 366mm 11.0”; 280mm 3.8”; 97mm 10.05 lb; 4.54 kg |
15.4"; 391mm 11.0"; 280mm 4.2"; 107mm 12.1lb; 5.5 kg |
Environmental | Recommended operating temperature 41F to 95 F; 5C to 35C Recommended storage temperatures –4F to 159F; -20C to 70C |
||
Firmware | Upgradeable with BatteryShop™ over the Internet, flash memory. Lifetime upgrade subscription available. | ||
Approvals | Tested and approved by ITS to comply with CSA/UL/CE standards. RoHS and WEEE compliant. | ||
Warranty | Cadex warrants the analyzer against defective materials and workmanship for a period of two (2) years from the original purchase date. |
* Specifications subject to change
Udfyld formularen for at forespørge om produktet. Kun salg til erhverv.